Lymphocyte Depletion Kinetics Form Help
- This tool requires the following to yield a valid result
- Values must be entered in units of: [measured value] x 109 cells/liter
- Values must be in the following ranges
- Entering > 7.0 x 109 cells/liter will yield warning message:
"Lymphocyte count is out of range"
- Entering < 0.007 x 109 cells /liter will yield warning message:
"Lymphocyte count is out of range"
- For calculations using a single absolute lymphocyte count,the following condition must be present for this tool to calculate a radiation dose
- Lymphocyte count is > 0.007 x 109 cells/liter and ≤ 1.35 x 109 cells/liter
- For calculations using multiple absolute lymphocyte counts, the following conditions must be present for this tool to calculate a radiation dose
- At least one total lymphocyte count must be ≤ 1.35 x 109 cells/liter OR
- One blood draw must occur ≥ 36 hours after exposure
- Time range for drawing blood for the lymphocyte depletion kinetics tool
- Latest allowable time: 264 hours (11 days) after the "date/time of exposure"
- The tool will not allow entry of any measurements taken before time of exposure.